IfcWasteTerminalTypeEnum
IfcWasteTerminalTypeEnum
Definition from IAI: The IfcWasteTerminalTypeEnum defines the range of different types of waste terminal that can be specified.
HISTORY: New type in IFC 2x2
Enumeration
Value | Definition | Pset |
FLOORTRAP | Pipe fitting, set into the floor, that retains liquid to prevent the passage of foul air | YES |
FLOOORWASTE | Pipe fitting, set into the floor, that collects waste water and discharges it to a separate trap. | YES |
GULLYSUMP | Pipe fitting or assembly of fittings to receive surface water or waste water, fitted with a grating or sealed cover. | YES |
GULLYTRAP | Pipe fitting or assembly of fittings to receive surface water or waste water, fitted with a grating or sealed cover and discharging through a trap (BS6100 330 3504 modified) | YES |
GREASEINTERCEPTOR | Chamber, on the line of a drain or discharge pipe, that prevents grease passing into a drainage system (BS6100 330 6205). | YES |
OILINTERCEPTOR | One or more chambers arranged to prevent the ingress of oil to a drain or sewer, that retain the oil for later removal (BS6100 330 67316). | YES |
PETROLINTERCEPTOR | Two or more chambers with inlet and outlet pipes arranged to allow petrol/gasoline collected on the surface of water drained into them to evaporate through ventilating pipes. | YES |
ROOFDRAIN | Pipe fitting, set into the roof, that collects rainwater for discharge into the rainwater system. | YES |
WASTEDISPOSALUNIT | Electrically operated device that reduces kitchen or other waste into fragments small enough to be flushed into a drainage system. | YES |
WASTETRAP | Pipe fitting, set adjacent to a sanitary terminal, that retains liquid to prevent the passage of foul air. | YES |
USERDEFINED | ||
NOTDEFINED |
EXPRESS specification:
|